hzconnectors560x135

HZ Connectors


Hot rolled connector sections RZD, RZU and RH are fitted to HZ/HZM king piles so that on site the king piles can be pitched and driven straight away. The RZD and RZU sections connect the intermediary AZ sheet piles to the HZ/HZM king piles to form a continuous wall. The RH section is used to join double king piles or to construct continuous C1 or C23 combination king pile walls.

HZ Connectors

Section Dimensions Sectional 
Area
Coating Area Mass Section Modulus  Moment of Inertia
  h
mm
b
mm
a
mm
ay
mm
cm2 m2/m kg/m y-y cm3 z-z cm3 y-y cm4 z-z cm4
RZD 16 61.8 80.5 - 31.5 20.7 0.18 16.2 18 22 57 94
RZD 16 61.8 80.5 - 38.3 20.4 0.18 16.1 18 22 68 94
RH 16 61.8 68.2 12.2 32.5 20.1 0.19 16.0 25 16 83 54
RZD 18 67.3 85.0 - 35.9 23.0 0.19 18.1 22 25 78 110
RZD 18 67.3 85.0 - 42.1 22.6 0.19 17.9 22 25 92 110
RH 20 67.3 79.2 14.2 36.5 25.2 0.21 20.0 33 22 122 88

Suitable King Pile
RZD 16: HZ 775 A-B, HZ 975 A-B, HZ 880 M, HZ1080 M, HZ 1180M A-B
RZU 16: HZ 775 A-B, HZ 975 A-B, HZ 880 M, HZ1080 M, HZ 1180M A-B
RH 16: HZ 775 A-B, HZ 975 A-B, HZ 880 M, HZ1080 M, HZ 1180M A-B
RZD 18: HZ 775 C-D, HZ 975 C-D, HZ 1180M C-D
RZU 18: HZ 775 C-D, HZ 975 C-D, HZ 1180M C-D
RH 20: HZ 775 C-D, HZ 975 C-D, HZ 1180M C-D


More

Ask A Question


By clicking Submit you are agreeing to our Terms & Conditions and Privacy Policy | * Denotes a mandatory field.